Small Appliance Repair : Once you've tackled the furnace, a toaster or blender seems like child's play. Find out how to fix them here. Thermostat Maintenance : To make sure there's actually a problem with your heating system, you may want to check the thermostat, too. Learn how to calibrate a thermostat.
Oil Furnace Maintenance Tips While there aren't many quick fixes you can undertake yourself on these types of furnaces, good regular maintenance can help eliminate many problems. Here are a few oil furnace maintenance tips: During the heating season, check the smoke from the chimney. If the smoke is black, the furnace is not burning the oil completely and fuel is being wasted. Call a professional service person for adjustments.
Clean the blower at the beginning of the heating season and again about midway through the season. Clean soot from the stack control about midway through the heating season.
If the blower motor has grease or oil fittings, lubricate the fittings midway through the heating season with cup grease or weight nondetergent motor oil not all-purpose oil , available at hardware stores. Clean the thermostat before each heating season. If your furnace still isn't working, use the handy troubleshooting chart on the next page to find a solution. Troubleshooting Oil Furnaces and Oil Heaters Cleaning or replacing filters is a job anyone can do, and often it's the reason an oil furnace isn't performing at peak levels.
Use this chart to see if the problem with your furnace might be fixed with a filter change. How To Clean and Replace Oil Furnace Filters The oil filter should be changed or cleaned at the start of the heating season and about midway through the season.
Here's how to clean or replace the filter: Step 1: Close oil shutoff valve between fuel tank and filter. Step 2: Unscrew bottom or cup of filter housing, and remove filter. Step 3: If filter is disposable, insert new one of same size and type. If furnace has permanent filter, clean filter according to furnace manufacturer's recommendations.
Step 4: Replace old filter gaskets with new ones. Step 5: Screw in bottom of housing, and open oil shutoff valve. Clean this strainer when you clean the oil filter. Here's how: Step 1: Unbolt cover of pump housing where oil line enters burner , and lift off cover. Step 2: Remove thin gasket around rim. Find and remove strainer, which is a cylindrical or cup-shape wire mesh screen.
What You'll Need You'll want to have these tools on hand to clean the pump strainer: Wrench Kerosene Old, soft toothbrush Replacement pump strainer and gasket Step 3: Soak strainer in kerosene for several minutes to loosen any built-up sludge. Carefully clean strainer with old, soft toothbrush. Step 4: Inspect strainer. If it's torn or badly bent, replace it with new pump strainer of the same type.
Step 5: Set strainer into place on pump, place new gasket on rim, and bolt cover of pump housing back on. Sometimes the problem is not in the filter but the stack control, a safety device that shuts down the furnace. Find out how to check it and what to do about it on the next page. How To Clean the Oil Furnace Stack Control The stack control of the oil furnace, located in the stack, is a safety device that monitors the operation of the oil burner.
If the burner fails to ignite, the stack control shuts off the motor. Frequently, however, a furnace shutdown is caused by a malfunctioning stack control rather than by the burner. What You'll Need You'll want to have these tools on hand to check the stack control: Wrench Brush Soapy water Soft cloth Newspaper Refractory cement If the burner fails to ignite, first check the fuel tank and refill it if necessary. If the tank doesn't need to be refilled, press the reset button on the stack control.
If the burner doesn't ignite after you've pressed the button once, clean the control, as detailed below. Then press the reset button again. If the burner still doesn't operate, call a professional service person. The stack control gradually becomes coated with soot during the heating season. To keep it working properly, clean the control every month or as soon as it becomes soot-covered. Here's how to clean the stack control: Step 1: Remove bolts that hold control in stack. Pull out sensor and its housing.
The company is seeking candidates that are looking for a workplace in which to grow and prosper. Our technicians are responsible for maintaining, repairing, and servicing gas and oil burners at various customer locations throughout the New York Metropolitan area.
Our technicians can adjust and install various commercial temperature controls and devices and have a working knowledge of electrical circuits and troubleshooting. All our technicians can fire and adjust Controlled Combustion. ACV Enviro is a full service environmental company providing industrial maintenance, field and emergency response services. Must have valid drivers license. ACV Enviro is a clean shaven and drug free workplace.
ACV Enviro. United Metro Energy Corporation. We also offer paid time off PTO , a k plan, flexible hours, incentive programs, an end-of-year bonus, employee events, continued training, and a supportive work environment.
Our service technicians also enjoy access to integrated software, company uniforms, a fully-stocked warehouse and take Overtime work. Blue Bear Plumbing in Pembroke, MA is actively seeking a full-time Oil Burner Service Tech to troubleshoot, diagnose, service, repair, and perform maintenance on oil burning systems.
Are you proud of the work you do? Are you looking for a successful career-path with a company that values you? Are you looking to advance your career? If so, please read on! We provide wonderful benefits and perks , including medical, dental, vision, a k plan, annuity, and pension. If this sounds like the right Oil Burner Service Tech opportunity for you, apply today! Our company motto is service with integrity.
Delivering affordable, efficient, and quality services is the foundation Blue Bear Plumbing. We are proud of our reputation for putting clients first and getting the job done right the first time, every time.
We are a team of qualified experts dedicated to living our code of values of Respect, Integrity, and Customer Focus while having fun in the process! As Service Professional Technician, you are a key member of our team responsible for the quality and efficient installation, service, maintenance of heating and air conditioning systems.
You will also develop new customers by identifying opportunities to sell additional work. Exemplifying our code of values by showing respect and courtesy to all customers and employees. Ideally you have prior experience in the HVAC industry and have proven communication skills with Aire Serv Careers.
Atlantic Fuels is seeking experienced full-time oil and propane technician to help grow our residential propane delivery and service division.
There are pros and cons to being an oil burner technician. The work may be appealing for people with good mechanical, reading and math skills. Based on data from the Bureau of Labor Statistics BLS , experienced oil technicians can expect to find work in the coming years.
This is especially true for those seeking employment with large residential and commercial properties. On the flip side, oil burner technicians may have to work at sites where the heating and cooling systems are broken, so the temperatures could be excessively hot or cold.
Irregular hours and having to work in tight spaces can also be part of the job. That same year, there were , of these jobs in the United States, and the outlook for the next 10 years showed a four-percent increase in available jobs. This growth is driven by residential and commercial building construction, so BLS predicts that HVACR technician work opportunities will be good in the coming years.
Commercial and residential building construction is expected to drive employment growth, and job opportunities for HVACR technicians are expected to be readily available. These positions generally require advanced degrees and additional experience, though.
0コメント